GENERAL CHEMICAL CORP -- AMMONIUM ACETATE, CRYSTAL -- 6810-00-234-7209
===================== Product Identification ===================== Product ID:AMMONIUM ACETATE, CRYSTAL MSDS Date:10/01/1989 FSC:6810 NIIN:00-234-7209 === Responsible Party === Company Name:GENERAL CHEMICAL CORP Address:90 E HALSEY RD Box:395 City:PARSIPPANY State:NJ ZIP:07054 Country:US Info Phone Num:800-631-8050 Emergency Phone Num:800-631-8050 CAGE:0AU44 === Contractor Identification === Company Name:GENERAL CHEMICAL CORPORATION Address:90 EAST HALSEY ROAD Box:City:PARSIPPANY State:NJ ZIP:07054 Country:US Phone:973-515-1840 CAGE:0AU44 ============= Composition/Information on Ingredients ============= Ingred Name:"NOT HAZARDOUS" Other REC Limits:NONE SPECIFIED ===================== Hazards Identification ===================== LD50 LC50 Mixture:ORAL LD50 (RAT): 632 MG/KG Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:INHALATION-OF DUST OR MIST CAN BE MODERATELY IRRITATING TO RESPIRATORY TRACT. INGESTION-MAY IRRITATE MOUTH, ESOPHAGUS, STOMACH. MAY BE HARMFUL. ESTIMATED TO BE MODERATELY TOXIC. SKIN-MAY CAUSE IRRIGAT ION. EYE-MODERATELY IRRITATING. Explanation of Carcinogenicity:NONE OF THE CHEMICALS IN THIS PRODUCT IS LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN. Effects of Overexposure:INHALATION-BREATHING DIFFICULTIES. INGESTION-CAN CAUSE NAUSEA, DIARRHEA, DIURESIS AND SYSTEMIC AMMONIA POISONING. EYE/SKIN-IRRITATION. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:EYE-FLUSH PROMPTLY WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. SKIN-WASH WITH SOAP & WATER; THEN FLUSH WITH WATER UNTIL CHEMICAL IS REMOVED. INGEST-IF CONSCIOUS, IMMEDIATELY GIVE 2 TO 4 GLASSES OF W ATER AND INDUCE VOMITING BY TOUCHING BACK OF THROAT WITH FINGER. INHALE-REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT, GIVE OXYGEN. GET MEDICAL ATTENTION FOR EYE/SKIN CONTACT, INGESTION, INHALATION. ===================== Fire Fighting Measures ===================== Autoignition Temp:Autoignition Temp Text:UNK Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY CHEMICAL; ATTACK FIRE FREELY WITH WATER. ANY AGENT MAY BE USED. Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE CLOTHING INCLUDING SAFETY GOGGLES. USE WATER SPRAY TO KNOCK DOWN FUMES & TO COOOL FIRE EXPOSED CONTAINERS. Unusual Fire/Explosion Hazard:CRYSTAL IS REPORTED TO BE COMBUSTIBLE. IRRITATING GASES MAY BE PRODUCED WHEN HEATED & ALSO BURN. PRESSURE DEVELOPED BY EVOLVED AMMONIA CAN RUPTURE SEALED CNTNR. ================== Accidental Release Measures ================== Spill Release Procedures:SWEEP UP AND PLACE IN A CONTAINER FOR DISPOSAL. FLUSH RESIDUE AWAY WITH WATER AND ATTEMPT TO KEEP OUT OF SEWER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN COOL, VENTILATED, DRY AREA OF LOW FIRE RISK. KEEP CONTAINER TIGHTLY CLOSED. PROTECT FROM PHYSICAL DAMAGE. Other Precautions:NONE ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE A NIOSH-APPROVED DUST OR MIST RESPIRATOR, AS APPLICABLE TO AVOID INHALATION. Ventilation:PROVIDE LOCAL EXHAUST, IF DUSTY OR MISTY CONDITIONS PREVAIL. NATURAL VENTILATION IS ADEQUATE IN THE ABSENCE OF DUST OR . Protective Gloves:WEAR GLOVES Eye Protection:SAFETY GOGGLES Other Protective Equipment:WEAR REGULAR WORK CLOTHES, INCLUDING LONG-SLEEVED SHIRT & TROUSERS. Work Hygienic Practices:USE NORMAL PERSONAL HYGIENE AND FOLLOW GOOD HOUSEKEEPING PRACTICES. Supplemental Safety and Health ================== Physical/Chemical Properties ================== HCC:N1 Boiling Pt:B.P. Text:DECOMPOSES Melt/Freeze Pt:M.P/F.P Text:237F,114C Vapor Pres:NEGLIGIBLE Spec Gravity:1.07-1.17 pH:7.0 Solubility in Water:60 @ 4C Appearance and Odor:COLORLESS OR WHITE DELIQUESCENT CRYSTALS. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZERS, INCLUDING SODIUM HYPOCHLORITE, ACIDS, & BASES. Stability Condition to Avoid:EXTREMELY HIGH TEMPERATURES (DECOMPOSITION OCCURS ABOVE 237F) Hazardous Decomposition Products:IRRITATING VAPORS OF AMMONIA AND ACETIC ACID MAY BE P RODUCED WHEN HEATED. THESE GASES CAN ALSO BURN AND ARE REACTIVE. ==================== Disposal Considerations ==================== Waste Disposal Methods:IF REGULATIONS PERMIT, CRYSTAL AMMONIUM ACETATE MAY BE DISPOSED OF VIA A SECURE SOLID WASTE LANDFILL OR DILUTED AND FLUSH TO SEWER. DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL RE GULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.